Agg writes "Well the slab gets poured on Wednesday so I thought I would sink 6 meters of copper pipe in the slab so that I can run my water loop through it when the house is finished. I hope to have water year round at about 16deg [about 61F]. No need for radiators or fans with chilled water coming straight out of the slab!"
Talk about a heat sink.
I'm a little surprised that this sort of technique is not more widely adopted at places like data centers; geothermal or water-source heat exchange, especially for cooling.
I have been looking at using a water-source heat pump system to replace my electrical resistance heating/air conditioning system. Big incentives from the government.
There is a data center in WA state that keeps half of its' property as vacant land for the sole purpose of using it as a giant heat exchanger. Looks like about an acre. They have piping about 16 inches underground throughout the field. I am told it works great.
That is why I wondered why some data corp hasn't bought up the old Titan 2 missile silos we have here in AR and turned them into datacenters. They are VERY deep in the ground, so you have natural cooling there, they are on the side of a mountain with lots of wind, more cooling, and if you put the racks into the silos themselves you could have fresh air blowing straight up and out through the silos. there are also lots of fiber lines running through that area, including dark fiber left by the telecos during the dotbomb. Not to mention with those big steel doors and hardened everything breaking into your data center would be pretty damned difficult, if not impossible. Oh and we have nuclear power here, so electricity is cheap compared to surrounding states.
It always seemed to me that with datacenters needing so much cooling these would be a natural fit. The military has done all the hard work, and from what I heard they sell them pretty cheap. One guy even bought one and turned it into an underground house for his family. Just always seemed to me to be the way to go.
Depends on who you've contracted the work out to. I'm not kidding. Some inspectors "know" the contractors such that they only do a cursory inspection of the finished product before signing it off.
Why? It's very similar to what they do when laying radiant heat into the floor (which is very nice btw, over ducted heat, helps with breathing problems).
Also, like a previous comment suggesting, maybe you should look into radiant heat tubing over copper.
"Also, like a previous comment suggesting, maybe you should look into radiant heat tubing over copper."
This. I used to live in Alaska and radiant heat slabs were very common. The problem was making sure they never went without heat in the winter. If they did, you ended up with burst pipes and a cracked slab. Big headache.
The fix is burst-resistant flexible tubing. There is a product called Aqua-pex that fits the bill perfectly. Does not burst when frozen, has a 100-year warranty and is easy to install as it is flexible.
The other problem with copper in concrete is that the concrete itself is corrosive. It WILL eventually eat through the pipes leading to all sorts of headaches. Usually, when this happens the only fix is drain them and cap the pipes. Most people in Alaska with radiant flooring, even when using Aqua-pex, lay down a second circuit in case there is a problem. They simply hook up the back-up.
Another suggestion. If you DO use copper tubing, use alcohol, or some other coolant such as glycol, rather then water. You will have better heat transfer as well as less corrosion. This is, of course, assuming you have a closed loop circuit (would be foolish to have anything but).
Okay, I get it, he got the informative for the Aqua-pex. Problem is, Ethlyene glycol decreases water's ability to transfer heat. What it does is raise the boiling point, lower the freezing point, and retard corrosion. Replace your coolant mixture when a voltage measurement between fluid and pipe exceeds one volt.
We used to use alcohol in radiators, because it does all that stuff and increases thermal conductivity, too. But there were some problems with fires when people used too much. So we just stopped. If you put 100% ethlene glycol coolant in your cooling system it will work, albeit at a very poor efficiency. You might get away with it in the winter.
If you want something you can just use a little of, there is Red Line Water Wetter, which is often used in racing in all-alloy systems, in which it is sufficient to prevent corrosion. It actually also increases thermal transfer.
Unless there's a specific code against it there's no reason why he wouldn't be able to. I work with the Building and Plans department at a county-level government office (I actually admin their software system). When I went through their checklists to add to the new system, it was mostly things you're supposed to do, rather than things you're NOT supposed to do. As long as you do everything on the list you're good to go.
That site says that concrete does not corrode copper. My experience seems to back that up. (Yes, I've built and I've demolished buildings.)
One problem that might cause corrosion, is allowing anything to be electrically grounded through the copper. Read the link. Using a double insulated pump would be a good idea, but not necessary.
I care; a.) how much copper, btw doesn't concrete corrode copper which is the reason why it isn't placed in the slab anyways. b.) for each layer of piping you put down you need an additional 3 inches of slab. proper embedment really requires 3" of coverage else the concrete will crack. c.)concrete curing is an exothermic reaction and it takes your typical slab at least a year to completely cure.
Here is the best part, I'm assuming your in a cold climate with a reasonable frost line (otherwise this would be a stupid idea). If the water in teh pipes stop circulating and freeze it will crack the pipe and the concrete and cause I nice leak. again weakening the concrete overall stress.
I'm IAAAA ( I am an actual architect) so heed the warning. Or do it properly.
btw doesn't concrete corrode copper which is the reason why it isn't placed in the slab anyways.
Not really. According to this article [copper.org], copper should be fine when embedded in concrete so long as the sulfur content in the concrete additives are minimal.
3" cover is most certainly not required. Most commercial floor slabs are 2.5" concrete on 1/2" form deck (9/16 for the pedantic). A 4" slab will have two layers of rebar in it - either as WWR (gauge wire on a 6x6 grid) or as actual rebar up to 1/2" in diameter. That means as little as 1-1/2" of cover over the steel.
The 3" you may be thinking about is clear cover for steel reinforcement when slabs are cast against earth. In that case, it's to minimize water infiltration and protect the steel from corrosion.
Freezing of the slab is theoretically possible in a very, very cold environment, but not unless the house is left unheated for an extended time as subzero temps and the typical ground temp is below freezing (an ice lens would have to be able to extend from the exterior of the slab all the way to where the embedded pipes are). In that case the whole house would have to be "winterized" with all lines drained.
"( I am an actual architect)" and "requires 3" of coverage else the concrete will crack."
You may be an architectural student. Rebar and remesh are placed within an inch of the surface to strengthen the exposed surfaces, edges, and corners. This copper tubing can be interlaced with the rebar, with no affect on the strength of the concrete, or increasing the likelihood of cracking.
You are right though, that for optimal cooling, the tubing should have 3 inches or more of concrete above and below it. Digging a trench for a heavy-up would do the trick.
I got a bunch of raised eyebrows when I had two four-gang electrical outlets (one from either leg of the house power) and an exhaust vent fan installed in one of my closets when we built our house. I wanted it for a server farm but couldn't convince anyone that I wasn't going to be farming something else.
If it was really an issue... plug up the holes and don't tell anyone? They're 6 meters long, not 6 meters wide; it shouldn't be too difficult.
Oh you definitely want to tell the new owner what it is. Though, the thought of someone finding the tubes and digging up the foundation to find out where they're connected to the water main only to find out they are just a giant loop is kinda funny.
I imagine a cartoon-like scenario, of a curious party feeding a flexible snake into one end of the pipe, trying to feel out how far it goes before terminating, only to have it come out the other end and poke them in the butt.
The steel rebar and the copper pipe being in close proximity will make them act as electrodes on a battery. This will cause the steel anode to slowly be destroyed by the chemical reaction.
Is it a practical concern in your case? I doubt it, but if they haven't poured yet, it wouldn't hurt to wrap the copper pipe in some PVC tape. This will reduce the thermal coefficient though. Maybe just do it where it passes within a couple inches of the rebar.
If you were pouring the concrete, why didn't you put it outside of the concrete [japru.com]? You would probably incur less structural risk... although I doubt a pipe that small would have much effect. More and more people are building new houses with geothermal exchange [geocomfort.com] to help mitigate costs in heating and cooling.
That first link is so bizarre, sitting within a post which otherwise seems very logical. My brain is short circuiting as it tries to find the connection between underground piping and spinach pizza.
In most areas of the country, it's not a question of if but when your house settles and puts some nice big cracks in your concrete. Whether or not it would be a enough to damage the pipe is another question, but if you're relying on it to cool a semi-expensive piece of hardware, I might be a little nervous about it.
Also, seems like this will severely limit your options for where to put your computer physically.
Are fans really that horrible? They make them fairly quiet now. Is that extra.4 Ghz really worth all that kind of effort?
Ground Source heating/cooling is a pretty nifty technology, and can be applied to a whole house HVAC system, rather than just a computer. It obviously requires more tubing than a single computer would, and in most climate will still require some supplemental heating/cooling for more extreme temperature days, but it's still awesome. It does have some upfront costs though.
This idea to do it for a particular computer is a clever idea. I personally wouldn't want the pipe to actually be moving horizontally through my slab, I'd rather dig as small a diameter hole as is possible, but deeper under the slab, and just have the line penetrate the slab vertically. The deeper you go, the more stable the temperature becomes, and the less hollow copper pipe you've got running through the slab, the less you weaken it.
Getting rid of heat by dumping it into the ground is a great idea.
The problem is, you're dumping heat into your house's slab, not the ground. You need to put the pipes several feet underground.
All this is is a mild underfloor heating system. If that's what you're trying to achieve, ok, but if you're also paying for air conditioning to remove heat from the house, this is probably not worth it.
Apart from the fact that concrete attacks copper. All copper water pipes placed in concrete have to coated in plastic to protect them (at least in the uk).
I would use underfloor heating plastic pipes which are designed for this job. Sure they would need to be longer to get the heat transfer but the price would be similar and would be far less likely to leak. They certainly work fine in getting 6kW of heat into my house so absorbing a few hundred Watts would not be a problem.
I rented a house in Kentucky that had this problem. The house was built with copper pipes embedded in the foundation for water, but to save money apparently the builder had just put bare copper pipe instead of putting it in plastic conduit. About 5 years after the house was built, the pipes started failing (in my case, it was a pipe that led to an outside faucet I never used, and I only discovered it when my water bill went from its normal $20 to about $280 one month).
Fortunately, the landlord in my case was the builder, so he sent a team out to reroute all the pipes up through the ceiling (which was a major mess, but the workers were really careful with my stuff and used sheet plastic generously to contain all the drywall dust, etc) and refunded my water bill for the month. He also replaced all the carpet in the house, since the workers pretty much ruined the carpeting running the new water pipes. So after a week or so of hassle, I had a freshly-painted house with brand new carpeting.
Apparently (as it was explained to me by the landlord) bare copper *can* sometimes work in concrete, but it depends on the acidity of the concrete, which probably depends on the stone and filler used. The landlord admitted he messed up and didn't measure the acidity of the concrete (and he had built and sold a lot of houses in my neighborhood, so he was looking forward to a LOT of repairs like this).
In any case, lining the copper with something is probably a good idea, even if it does reduce heat exchange. Or just use radiant heat pipe as the parent suggests.
After all, there's the heat generated by a computer (maybe 150 watts) to deal with, and 6 meters of pipe. With that much pipe, just the copper exposed to air would probably dissipate enough heat without needing forced air, so exchanging the heat through plastic into a concrete biomass should work just fine.
6 ft down doesn't actually provide much cooling. If you want a "neutral" temp, you need to go well underneath the slab.
Plus, you're "sinking" to a temp of 40-50F, and you have to consider that the concrete itself is a fair insulator, so you won't actually lose as much heat as you hope.
This is exactly what I came in here to say. Your concrete isn't some magical source of coolness: it obeys the laws of thermodynamics just like everything else. And a mere 6 meters of pipe means that that warm water is going to circulate frequently, warming up the concrete and making your computer overheat.
Putting the pipe in the slab won't have any effect on the slab or the resale of the house, but it probably won't have any effect on your computer either.
If you want to try some kind of fan-free passive cooling, you'd be better off putting in a swimming pool, and running some radiant pipe in the deep end...Fractionally heat your pool, and significantly cool your computer (unless you live in a really hot area).
He's barely going down at all. Maybe two feet deep, tops. His slab, at that depth, is going to have an insignificant (less than 15F) temperature difference with the external.
Now if you go down SIGNIFICANT distance, you can reach an earth-neutral temperature. The further down you go (until you reach a stable point, which will depend on your local ground type) the cooler you will be.
If he were to go down 10+ feet or so, and then set up the circuit like he is indicating, it wouldn't be too bad. As it stands, he's gonna have one of the most inadequate foundation slabs I've seen in any case, and his "copper pipe cooling" is not going to give him nearly the cooling he is hoping for. I hope to god he isn't in an area with frequent foundation shifts, or he's fucked as it is, copper piping or no.
PS: rechecked location. He's in Tassie, Australia. Very coastal, very similar temperature-wise to coastal US temps. Yeah. This is gonna be REAL disappointing for him. The laws of thermodynamics, much like gravity, don't play very well with wishful thinking.
While we all appreciate the thoughtful and incisive commentary on the appropriate symbol for "feet", I must humbly point out you misspelled "apostrophe", which has the unfortunate effect of putting your credibility as a master of punctuation in some... doubt.
But yes, since Slashcode fails to recognize ANY of the HTML4 entities for "prime" , we will have no choice but to fall back on that ancient artifact of the bygone typewriter era: the apostrophe key. I blame GP commentor's lamentable faux pas in choosing the wrong key on a lack of training in typewriter keyboarding. This modern computer keyboarding is an anarchic madhouse of unregulated freedom and undisciplined overabundance of choices. It's good to have the leadership and mentorship of those who know better, in order to provide guidance to youngling slashdotters. Thank you, evilbessie.
Resale value of house? (Score:5, Insightful)
Re:Resale value of house? (Score:5, Informative)
Parent
Very clever idea. (Score:5, Informative)
Parent
Re:Very clever idea. (Score:5, Interesting)
Parent
Re:Very clever idea. (Score:5, Interesting)
That is why I wondered why some data corp hasn't bought up the old Titan 2 missile silos we have here in AR and turned them into datacenters. They are VERY deep in the ground, so you have natural cooling there, they are on the side of a mountain with lots of wind, more cooling, and if you put the racks into the silos themselves you could have fresh air blowing straight up and out through the silos. there are also lots of fiber lines running through that area, including dark fiber left by the telecos during the dotbomb. Not to mention with those big steel doors and hardened everything breaking into your data center would be pretty damned difficult, if not impossible. Oh and we have nuclear power here, so electricity is cheap compared to surrounding states.
It always seemed to me that with datacenters needing so much cooling these would be a natural fit. The military has done all the hard work, and from what I heard they sell them pretty cheap. One guy even bought one and turned it into an underground house for his family. Just always seemed to me to be the way to go.
Parent
Re:Resale value of house? (Score:5, Funny)
Or sell the house to Ted Stevens and tell him that's where his Internet comes out of.
Parent
Sell it? Get it past inspectors (Score:4, Insightful)
that is what I want to know.
Parent
Re:Sell it? Get it past inspectors (Score:4, Insightful)
Depends on who you've contracted the work out to. I'm not kidding. Some inspectors "know" the contractors such that they only do a cursory inspection of the finished product before signing it off.
Parent
Re:Sell it? Get it past inspectors (Score:5, Interesting)
Why? It's very similar to what they do when laying radiant heat into the floor (which is very nice btw, over ducted heat, helps with breathing problems).
Also, like a previous comment suggesting, maybe you should look into radiant heat tubing over copper.
Parent
Re:Sell it? Get it past inspectors (Score:5, Informative)
"Also, like a previous comment suggesting, maybe you should look into radiant heat tubing over copper."
This. I used to live in Alaska and radiant heat slabs were very common. The problem was making sure they never went without heat in the winter. If they did, you ended up with burst pipes and a cracked slab. Big headache.
The fix is burst-resistant flexible tubing. There is a product called Aqua-pex that fits the bill perfectly. Does not burst when frozen, has a 100-year warranty and is easy to install as it is flexible.
The other problem with copper in concrete is that the concrete itself is corrosive. It WILL eventually eat through the pipes leading to all sorts of headaches. Usually, when this happens the only fix is drain them and cap the pipes. Most people in Alaska with radiant flooring, even when using Aqua-pex, lay down a second circuit in case there is a problem. They simply hook up the back-up.
Another suggestion. If you DO use copper tubing, use alcohol, or some other coolant such as glycol, rather then water. You will have better heat transfer as well as less corrosion. This is, of course, assuming you have a closed loop circuit (would be foolish to have anything but).
Parent
Re:Sell it? Get it past inspectors (Score:5, Informative)
Okay, I get it, he got the informative for the Aqua-pex. Problem is, Ethlyene glycol decreases water's ability to transfer heat. What it does is raise the boiling point, lower the freezing point, and retard corrosion. Replace your coolant mixture when a voltage measurement between fluid and pipe exceeds one volt.
We used to use alcohol in radiators, because it does all that stuff and increases thermal conductivity, too. But there were some problems with fires when people used too much. So we just stopped. If you put 100% ethlene glycol coolant in your cooling system it will work, albeit at a very poor efficiency. You might get away with it in the winter.
If you want something you can just use a little of, there is Red Line Water Wetter, which is often used in racing in all-alloy systems, in which it is sufficient to prevent corrosion. It actually also increases thermal transfer.
Parent
Re:Sell it? Get it past inspectors (Score:5, Informative)
Unless there's a specific code against it there's no reason why he wouldn't be able to. I work with the Building and Plans department at a county-level government office (I actually admin their software system). When I went through their checklists to add to the new system, it was mostly things you're supposed to do, rather than things you're NOT supposed to do. As long as you do everything on the list you're good to go.
Parent
Re:Sell it? Get it past inspectors (Score:5, Insightful)
Yeah, that 6m of copper tubing will probably make the house explode, right?
Parent
Re:Sell it? Get it past inspectors (Score:5, Informative)
http://www.copper.org/resources/properties/protection/underground.html [copper.org]
That site says that concrete does not corrode copper. My experience seems to back that up. (Yes, I've built and I've demolished buildings.)
One problem that might cause corrosion, is allowing anything to be electrically grounded through the copper. Read the link. Using a double insulated pump would be a good idea, but not necessary.
Parent
Re:Resale value of house? (Score:4, Insightful)
Who cares, it's a couple pipes sticking out of the slab. Cut 'em off if you're worried about it.
Parent
Re:Resale value of house? (Score:4, Interesting)
I care;
a.) how much copper, btw doesn't concrete corrode copper which is the reason why it isn't placed in the slab anyways.
b.) for each layer of piping you put down you need an additional 3 inches of slab. proper embedment really requires 3" of coverage else the concrete will crack.
c.)concrete curing is an exothermic reaction and it takes your typical slab at least a year to completely cure.
Here is the best part, I'm assuming your in a cold climate with a reasonable frost line (otherwise this would be a stupid idea). If the water in teh pipes stop circulating and freeze it will crack the pipe and the concrete and cause I nice leak. again weakening the concrete overall stress.
I'm IAAAA ( I am an actual architect) so heed the warning. Or do it properly.
Parent
Re:Resale value of house? (Score:4, Informative)
btw doesn't concrete corrode copper which is the reason why it isn't placed in the slab anyways.
Not really. According to this article [copper.org], copper should be fine when embedded in concrete so long as the sulfur content in the concrete additives are minimal.
Parent
Mod parent down (Score:5, Informative)
3" cover is most certainly not required. Most commercial floor slabs are 2.5" concrete on 1/2" form deck (9/16 for the pedantic). A 4" slab will have two layers of rebar in it - either as WWR (gauge wire on a 6x6 grid) or as actual rebar up to 1/2" in diameter. That means as little as 1-1/2" of cover over the steel.
The 3" you may be thinking about is clear cover for steel reinforcement when slabs are cast against earth. In that case, it's to minimize water infiltration and protect the steel from corrosion.
Freezing of the slab is theoretically possible in a very, very cold environment, but not unless the house is left unheated for an extended time as subzero temps and the typical ground temp is below freezing (an ice lens would have to be able to extend from the exterior of the slab all the way to where the embedded pipes are). In that case the whole house would have to be "winterized" with all lines drained.
IAASE (structural engineer), BTW.
Parent
Re:Mod parent down (Score:5, Funny)
damn SE always ruining an Architects fun .... :)
Parent
Re:Resale value of house? (Score:4, Informative)
"( I am an actual architect)" and "requires 3" of coverage else the concrete will crack."
You may be an architectural student. Rebar and remesh are placed within an inch of the surface to strengthen the exposed surfaces, edges, and corners. This copper tubing can be interlaced with the rebar, with no affect on the strength of the concrete, or increasing the likelihood of cracking.
You are right though, that for optimal cooling, the tubing should have 3 inches or more of concrete above and below it. Digging a trench for a heavy-up would do the trick.
Parent
Re:Resale value of house? (Score:5, Insightful)
How are you going to explain that if you want to sell that house???
Call it radiant floor heating?
Parent
Re:Resale value of house? (Score:5, Insightful)
I don't know about you, but if I buy or make something, it's for me. I'm not there to take care of it for the next owners. If I wanted that, I'd rent.
Parent
Re:Explanations (Score:5, Funny)
I got a bunch of raised eyebrows when I had two four-gang electrical outlets (one from either leg of the house power) and an exhaust vent fan installed in one of my closets when we built our house. I wanted it for a server farm but couldn't convince anyone that I wasn't going to be farming something else.
Parent
Re:Explanations (Score:5, Funny)
Parent
Re:Resale value of house? (Score:5, Funny)
Oh you definitely want to tell the new owner what it is. Though, the thought of someone finding the tubes and digging up the foundation to find out where they're connected to the water main only to find out they are just a giant loop is kinda funny.
Parent
Re:Resale value of house? (Score:5, Funny)
Apparently I'm 5 years old.
Parent
copper and steel don't mix (Score:5, Interesting)
The steel rebar and the copper pipe being in close proximity will make them act as electrodes on a battery. This will cause the steel anode to slowly be destroyed by the chemical reaction.
Is it a practical concern in your case? I doubt it, but if they haven't poured yet, it wouldn't hurt to wrap the copper pipe in some PVC tape. This will reduce the thermal coefficient though. Maybe just do it where it passes within a couple inches of the rebar.
This is not a concern (Score:5, Informative)
Houses have been built with copper pipes and steel rebar and rewire in the slab for decades now without any electrolytic effects showing up.
Once the concrete is cured, it is no longer an electrolyte. Concrete is not a great electrical insulator, but it's not a great conductor either.
Parent
Why Stop at Concrete? (Score:5, Insightful)
outside of the concrete (Score:5, Funny)
That first link is so bizarre, sitting within a post which otherwise seems very logical. My brain is short circuiting as it tries to find the connection between underground piping and spinach pizza.
Parent
Don't Use Copper (Score:5, Informative)
Use PEX instead. Copper will eventually fail. Look at the material that is used for radiant flooring.
Re:Don't Use Copper - wrong (Score:5, Informative)
Negative.
http://www.copper.org/applications/plumbing/techcorner/problem_embedding_copper_concrete.html [copper.org]
They use PEX because it is cheaper and easier to install, NOT because of its longevity.
Parent
Do not overclock your house (Score:5, Funny)
Without proper thermal throttling, your roof could come off, even with a passive heatsink.
I think Antec makes a two-story-high fan that might work perfectly in such a situation, but the neighbors might be bothered by the LEDs.
Concrete breaks you know (Score:4, Informative)
In most areas of the country, it's not a question of if but when your house settles and puts some nice big cracks in your concrete. Whether or not it would be a enough to damage the pipe is another question, but if you're relying on it to cool a semi-expensive piece of hardware, I might be a little nervous about it.
Also, seems like this will severely limit your options for where to put your computer physically.
Are fans really that horrible? They make them fairly quiet now. Is that extra .4 Ghz really worth all that kind of effort?
free cooling is, well, cool (Score:5, Informative)
Ground Source heating/cooling is a pretty nifty technology, and can be applied to a whole house HVAC system, rather than just a computer. It obviously requires more tubing than a single computer would, and in most climate will still require some supplemental heating/cooling for more extreme temperature days, but it's still awesome. It does have some upfront costs though.
This idea to do it for a particular computer is a clever idea. I personally wouldn't want the pipe to actually be moving horizontally through my slab, I'd rather dig as small a diameter hole as is possible, but deeper under the slab, and just have the line penetrate the slab vertically. The deeper you go, the more stable the temperature becomes, and the less hollow copper pipe you've got running through the slab, the less you weaken it.
It gets poured on wednesday .. (Score:4, Insightful)
Underfloor heating, anyone? (Score:5, Informative)
Getting rid of heat by dumping it into the ground is a great idea.
The problem is, you're dumping heat into your house's slab, not the ground. You need to put the pipes several feet underground.
All this is is a mild underfloor heating system. If that's what you're trying to achieve, ok, but if you're also paying for air conditioning to remove heat from the house, this is probably not worth it.
Re:Underfloor heating, anyone? (Score:4, Funny)
Parent
Re:It will work fine. (Score:4, Funny)
Just don't plan on being able to move your desk.
Copper would be a waste of money tho. Use one of the many types of plastic hose already made for this application.
Yes, because plastic is a muuch better conductor for heat than say, copper.
Parent
Re:It will work fine. (Score:5, Informative)
Apart from the fact that concrete attacks copper. All copper water pipes placed in concrete have to coated in plastic to protect them (at least in the uk).
I would use underfloor heating plastic pipes which are designed for this job. Sure they would need to be longer to get the heat transfer but the price would be similar and would be far less likely to leak. They certainly work fine in getting 6kW of heat into my house so absorbing a few hundred Watts would not be a problem.
Parent
Re:It will work fine. (Score:5, Interesting)
I rented a house in Kentucky that had this problem. The house was built with copper pipes embedded in the foundation for water, but to save money apparently the builder had just put bare copper pipe instead of putting it in plastic conduit. About 5 years after the house was built, the pipes started failing (in my case, it was a pipe that led to an outside faucet I never used, and I only discovered it when my water bill went from its normal $20 to about $280 one month).
Fortunately, the landlord in my case was the builder, so he sent a team out to reroute all the pipes up through the ceiling (which was a major mess, but the workers were really careful with my stuff and used sheet plastic generously to contain all the drywall dust, etc) and refunded my water bill for the month. He also replaced all the carpet in the house, since the workers pretty much ruined the carpeting running the new water pipes. So after a week or so of hassle, I had a freshly-painted house with brand new carpeting.
Apparently (as it was explained to me by the landlord) bare copper *can* sometimes work in concrete, but it depends on the acidity of the concrete, which probably depends on the stone and filler used. The landlord admitted he messed up and didn't measure the acidity of the concrete (and he had built and sold a lot of houses in my neighborhood, so he was looking forward to a LOT of repairs like this).
In any case, lining the copper with something is probably a good idea, even if it does reduce heat exchange. Or just use radiant heat pipe as the parent suggests.
After all, there's the heat generated by a computer (maybe 150 watts) to deal with, and 6 meters of pipe. With that much pipe, just the copper exposed to air would probably dissipate enough heat without needing forced air, so exchanging the heat through plastic into a concrete biomass should work just fine.
Parent
Re:It will work fine. (Score:4, Funny)
exchanging the heat through plastic into a concrete biomass should work just fine.
For the typical house built on top of a concrete mass, exchanging heat with it may work fine.
But if your house is built on on top of a concrete biomass, RUN! IT'S ALIVE!! RUN!!!
Parent
Well we've eliminated Kelvin (Score:4, Funny)
since those aren't degrees.
Parent
Re:Ice cooler! (Score:5, Informative)
6 ft down doesn't actually provide much cooling. If you want a "neutral" temp, you need to go well underneath the slab.
Plus, you're "sinking" to a temp of 40-50F, and you have to consider that the concrete itself is a fair insulator, so you won't actually lose as much heat as you hope.
Parent
Re:Ice cooler! (Score:5, Informative)
This is exactly what I came in here to say. Your concrete isn't some magical source of coolness: it obeys the laws of thermodynamics just like everything else. And a mere 6 meters of pipe means that that warm water is going to circulate frequently, warming up the concrete and making your computer overheat.
Putting the pipe in the slab won't have any effect on the slab or the resale of the house, but it probably won't have any effect on your computer either.
If you want to try some kind of fan-free passive cooling, you'd be better off putting in a swimming pool, and running some radiant pipe in the deep end...Fractionally heat your pool, and significantly cool your computer (unless you live in a really hot area).
Parent
Re:Ice cooler! (Score:4, Interesting)
Scratch that. Greater detail on the pics.
He's barely going down at all. Maybe two feet deep, tops. His slab, at that depth, is going to have an insignificant (less than 15F) temperature difference with the external.
Now if you go down SIGNIFICANT distance, you can reach an earth-neutral temperature. The further down you go (until you reach a stable point, which will depend on your local ground type) the cooler you will be.
If he were to go down 10+ feet or so, and then set up the circuit like he is indicating, it wouldn't be too bad. As it stands, he's gonna have one of the most inadequate foundation slabs I've seen in any case, and his "copper pipe cooling" is not going to give him nearly the cooling he is hoping for. I hope to god he isn't in an area with frequent foundation shifts, or he's fucked as it is, copper piping or no.
Parent
Re:Ice cooler! (Score:4, Interesting)
PS: rechecked location. He's in Tassie, Australia. Very coastal, very similar temperature-wise to coastal US temps. Yeah. This is gonna be REAL disappointing for him. The laws of thermodynamics, much like gravity, don't play very well with wishful thinking.
Parent
Re:Units... (Score:5, Funny)
Parent
Re:dont bother... whatever you do will be obsolete (Score:4, Funny)
Parent
Re:It works very well... (Score:5, Funny)
While we all appreciate the thoughtful and incisive commentary on the appropriate symbol for "feet", I must humbly point out you misspelled "apostrophe", which has the unfortunate effect of putting your credibility as a master of punctuation in some... doubt.
But yes, since Slashcode fails to recognize ANY of the HTML4 entities for "prime" , we will have no choice but to fall back on that ancient artifact of the bygone typewriter era: the apostrophe key. I blame GP commentor's lamentable faux pas in choosing the wrong key on a lack of training in typewriter keyboarding. This modern computer keyboarding is an anarchic madhouse of unregulated freedom and undisciplined overabundance of choices. It's good to have the leadership and mentorship of those who know better, in order to provide guidance to youngling slashdotters. Thank you, evilbessie.
Parent